NRC & TL Test Data
| |
ASTM C423 |
|
|
ASTM E-90 |
ASTM E-413 |
Freq
(Hz) |
Absorption
Coefficient |
NRC |
Freq
(Hz)
|
Specimen
TL
(dB) |
No. of
Deficiencies |
| 50 |
0.08 |
|
|
|
|
| 63 |
0.15 |
| 80 |
0.14 |
80 |
16.4 |
0 |
| 100 |
0.30 |
100 |
18.4 |
0 |
| 125 |
0.45 |
125 |
20.3 |
4 |
| 160 |
0.70 |
160 |
22.4 |
6 |
| 200 |
0.89 |
200 |
24.4 |
5 |
| 250 |
1.03 |
1.030 |
250 |
26.3 |
6 |
| 315 |
1.07 |
|
315 |
28.3 |
4 |
| 400 |
1.04 |
400 |
30.4 |
5 |
| 500 |
1.13 |
1.130 |
500 |
32.3 |
1 |
| 630 |
1.05 |
|
630 |
34.4 |
0 |
| 800 |
1.01 |
800 |
36.4 |
0 |
| 1000 |
1.02 |
1.020 |
1000 |
38.4 |
0 |
| 1250 |
1.02 |
|
1250 |
40.3 |
0 |
| 1600 |
0.98 |
1600 |
42.4 |
0 |
| 2000 |
1.00 |
1.000 |
2000 |
44.4 |
0 |
| 2500 |
0.94 |
|
2500 |
46.3 |
0 |
| 3150 |
0.88 |
3150 |
48.3 |
0 |
| 4000 |
0.84 |
4000 |
50.4 |
0 |
| 5000 |
0.84 |
5000 |
52.3 |
0 |
| 6300 |
0.84 |
|
|
|
| 8000 |
0.76 |
|

Submit your noise problem
& receive a FREE QUOTE
|